Xi'an Desun Uniwill Electronic Technology Co., Ltd.

Our Vision Aspire to be a leader in water quality monitoring - our pursuit is to be respected by customers, employees, partners and other companies in the industry. Core Values Rigorous, Efficient,

Manufacturer from China
Site Member
4 Years
Home / Products / Dissolved Oxygen Sensor /

50mA 0.5 W Optical Dissolved Oxygen Sensor continuous For Aquaculture

Contact Now
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Province/State:Shaanxi
Country/Region:china
Contact Person:MrsWang
Contact Now

50mA 0.5 W Optical Dissolved Oxygen Sensor continuous For Aquaculture

Ask Latest Price
Video Channel
Brand Name :Desun Uniwill
Model Number :DS-380
Place of Origin :China
MOQ :0~100 pcs
Price :$280.00 - $360.00/ Piece
Payment Terms :L/C, D/A, D/P, T/T
Supply Ability :0~1000 pcs
Delivery Time :7~ 15 working days
Packaging Details :Carton packaging
Measuring range :0~20mg/L
Response time :3 seconds
Protection level :IP68
Power supply :DC 6~12V
product material :POM/SS316/Titanium
Power consumption :< 0.5 W
Calibration method :One or Two-point calibration
Accuracy :1%
Maximum working pressure :6bar
Fluorescent cap life :1 year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

50mA 0.5 W Optical Dissolved Oxygen Sensor For Aquaculture

Feature

1.Free from chemical interferences such as sulfides

2.Small annual drift, fast response, and more accurate measurement

3.Free of maintenance, longer application cycle and lower cost of use

4.Fluor cap replacement is simple

5.Support RS-485, MODBUS protocol

Technical Parameters

Item Parameters
Model DS380
Principle Fluorescence analysis method
Measuring range 0~20mg/L or 0-200% saturation
Response time 3 sec
Accuracy 1%
Protection level IP68
Installation Submersible
Temperature sensor NTC
Temperature range 0~50°C
Temperature accuracy ±0.2°C
Output Support RS-485, MODBUS protocol
Power supply DC 6~12V, current <50mA
Size Φ26*155 mm
Probe cable length Default 5 m, customized 10m, 15 m and 30 m cable
Fluorescent cap life 1 year
Maximum working pressure 6bar
product material POM/SS316/Titanium alloy
Calibration method One or Two-point calibration
Power consumption < 0.5 W

Error Possible causes Solutions

The operation interface cannot be connected or do not display measurement results

Controller and cable

connection error

Reconnect the

controller and cables

Cable failure Please contact us

The fluorescent cap is not

tightened or damaged

Reinstall and tighten the fluorescent cap or replace the fluorescent cap

The measured value is too high,

too low or the value is continuously unstable

The outer surface of the fluorescent cap is attached by foreign objects Clean the outer surface of the fluorescent cap and agitate the probe during measurement
Fluorescent cap is damaged Replace the fluorescent cap
The fluorescent cap has exceeded its service life

Temperature measurement exceeds measurable range or garbled reading

Controller and cable connection error Reconnect controller and temperature sensor cable
Temperature sensor is attached to foreign objects Gently brush the attachment with a soft brush

50mA 0.5 W Optical Dissolved Oxygen Sensor continuous For Aquaculture

Inquiry Cart 0